E-Tech ET8 Dokumentacja Strona 475

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 618
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 474
Chapter 11. Performing Live Partition Mobility 441
Figure 11-4 hidsk reserve policy not set correctly
When the validation process is run, an error message similar to Figure 11-5 on
page 442 will be displayed.
This problem can be resolved by performing the following steps:
1. Shutting down the mobile LPAR on the local VIOS if running.
2. Modifying the mobile LPAR hdisk assignments on the local VIOS to none.
3. Using the chdev command to change the hdisks reserve policy to no_reserve.
4. Modifying the mobile LPAR hdisk assignments to the original assignments.
5. Refreshing the View/Modify Virtual Storage view on the remote VIOS.
Przeglądanie stron 474
1 2 ... 470 471 472 473 474 475 476 477 478 479 480 ... 617 618

Komentarze do niniejszej Instrukcji

Brak uwag