E-TECH ET8 (V4) CONTROL PANEL INSTALLER MANUAL
P88E
P89E
P96E
P97E
P98E
P91E
P95E
P90E
P87E
P85E
P86E
P83E
P84E
OPTION DESCRIPTION DEFAULT PAGE OPTION DESCRIPTION DEFAULT PAGE OPTION DESCRIPTION DEFAULT PAGE
Follow Me Tel. No.
Enable Radio Devices 18
none
none
1E Monitor to RESET OP OFF 28
Test Call Interval
84=168hrs
Enable Radio Keys 18
none
2E Monitor to STROBE OP OFF
Time before next Test Call
6=12 hours
Enable Radio Keys 915
none
3E Monitor to SONALERT OFF
1E
Auto Dialling, Pulse & DTMF
ON
42
User Code 1 (Master) 123
4E Monitor to SIREN OFF
2E Pulse Dialling always OFF
User Codes 215 none
5E Day Mode to RESET OP ON
3E DTMF Dialling always OFF
Entry Delay Time 1 20 sec
6E Day Mode to STROBE OP ON
1E Disable Dialler OFF 43, 44
45
46, 47
48, 49
50, 51
Entry Delay Time 2 6=60 sec
7E Day Mode to SONALERT OFF
2E Contact ID format ON
Exit Delay Time 60 sec
8E Day Mode to SIREN OFF
3E Audible DTMF format OFF
Siren Reset Time 5 min
1E 2sec Monitor Alarm OFF 29, 30
31
4E Audible PULSE Format OFF
Normal Zone Sens all zones
2E 2sec Day Alarm ON
5E
Contact ID + Audible DTMF
OFF
Vibration Sens. HighLow none
3E
Monitor Zones Entry Delay2
ON
6E
Contact ID + Audible PULSE
OFF
DoubleTrigger Zones none
4E Radio Key Chirp & Flash OFF
1E
Split Dial Pri/Sec Phone Nos.
OFF
Instant Zones
Zones 38
5E 50Hz Mains Frequency ON
2E Check for Dial Tone ON
Entry Delay 1 Zones Zone 1
6E Double Key Keypad Panic ON
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
4E 4 Dialling attempts ON
Handover Zones Zone 2
7E Keypad Fire Alarm OFF
1E AREA 1 Open/Close reports OFF
Entry Delay 2 Zones none
8E Keypad Medical Alarm OFF
2E AREA 2 Open/Close reports OFF
Lockout Zones All zones
Supervised Radio Zones none
3E Siren Chirp on Kissoff OFF
AREA 1 Zones All zones
1E Supervision RESET output OFF 32, 33
31
34, 35
36, 37
38
40, 41
4E Flash Strobe on Kissoff OFF
AREA 2 Zones none
2E Supervision STROBE output OFF
5E Forced Opening report ON
AREA1 Codes 18 All codes
3E Supervision SONALERT OFF
6E Delayed Closing Reports OFF
AREA1 Codes 915 All codes
4E Supervision SIREN output OFF
7E Manual Exclude Reports ON
AREA2 Codes 18 Code 1
5E Supervision AUX1 output OFF
8E Auto Exclude Reports ON
AREA2 Codes 915 none
6E Supervision AUX2 output OFF
1E Enable Test Calls ON
Monitor Mode Zones none
7E Supervision SpeedUp x 6 OFF
2E Mains Report Delay ON
24hr Zones none
8E Supervision SpeedUp x10 OFF
3E ListenIn to Dialler OFF
Day Zones none
Supervision Time 24 hours
4E Swinger shutdown ON
Reset OP Zones All zones
5E Line Fault Monitor OFF
Strobe Zones All zones
2E 3K3 Zone Resistors OFF
6E Line Fault to AUX2 OFF
Sonalert Zones All zones
3E Radio Panic Toggles AUX1 OFF
1E Enable Up/Download OFF
Siren Zones All zones
4E Radio Panic Pulses AUX1 OFF
2E Enable Direct Connect OFF
Aux 1 Zones none
5E Radio Arm unseal warning OFF
3E Enable Remote Arming OFF
Aux 2 Zones none
6E 24hr Zone Fire Siren OFF
4E Enable Remote Disarming OFF
1E Entry Beeps ON
7E 4th Button RadioKey AUX1 OFF
5E Enable Remote AUX control OFF
2E Ksw Monitor/Disarm OFF
8E Quiet chirps on Arm/Disarm OFF
6E Enable Remote Status report OFF
3E Ksw Arm/Disarm OFF
1E
1E
1E
ARM1 Pulse Output OFF
7E Enable Remote Event Report OFF
4E Tamper siren lockout ON
2E
2E
2E
ARM2 Pulse Output OFF
8E Enable Callback Mode OFF
5E Duress to Reset OP OFF
3E
3E
3E
Quiet Monitor Siren OFF
Required rings to answer 1 52
41
53
6E Auto Exclude Zones ON
4E
4E
4E
6 Beeps on Arming OFF
Clear Radio Devices
7E Auto KP display off OFF
5E
5E
5E
6E
6E
7E
8E
Radio Key Monitor Arm OFF
OFF
OFF
OFF
OFF
Clear Memory
8E Delay Arm1,2 outputs OFF
Clear panel options
1E Tamper to Reset OP ON
Telephone No.1 Primary none
Clear User codes
2E Tamper to Strobe OP ON
Telephone No.2 Secondary none
P99E
Set Installer code
000000
53
P93E
Report MISC. Restorals 914
All on
41
3E Tamper to Sonalert ON
Account No. 1 0000
4E Tamper to Siren ON
Account No. 2 0000
5E KP Panic to Reset OP ON
Report ZONE Alarms 18 All zones
6E KP Panic to Strobe Op ON
Report Duress
Report Radio Tamper
Report Medical
Report Radio Panic by User
Report K/P & K/S Panic
Report Radio Battery by device
Report Fire
Report Supervision fail
Report Panel Tamper
Report Panel Battery
Report External Tamper
Report Mains Fail
Report Keypad Tamper
Report Exit Install Mode
7E KP Panic to Sonalert ON
Report Zone Restorals 18
All zones
All on
8E KP Panic to Siren ON
Report MISC. Restorals 18
1E S/cut Memory display ON 27, 28
26
24, 25
22, 23
19
21
20
17, 18
16
14, 15
57
39
56
Report Multiple Zone alarms
none
2E S/cut Zone Exclude ON
3E S/cut Monitor Mode ON
4E S/cut Keypad Panic OFF
5E S/cut Area 1 Arm ON
6E S/cut Area 2 Arm OFF
7E Auto Exclude 2s Warn ON
8E Exit Time x 10 OFF
P70E
P71E
P12EP25E
P10E
P69E
P65E
P67
P60E
P27E
P28E
P29E
P30E
P31E38E
P39E
P61E
P62E
P63E
P64E
P66E
P68E
P00E
P01EP08E
P09E
P11E
P26E
P40E
P41E
P42E
P43E
P44E
P45E
P46E
P47E
P48E
P49E
P50E
P51E
P52E
P53E
P54E
P55E
P56E
P57E
P58E
P59E
P72E
P73E
P74E
P75E
P92E
P76E
P77E
P78E
P79E
Account No.2 Zones none
Report misc. ALARMS 1
8
Report misc. ALARMS 9
14
39
Telephone No. 3 for Test Calls
P80E
none
P81E
39
Telephone No.4 for Callback
none
41
1E Restoral immediately OFF
2E Restoral after Siren Time OFF
3E Restoral on Disarm & seal OFF
4E Restore on Disarm always ON
P82E
These options are available in User Program Mode.
ALL options are available in Installer Program Mode
ET8 (V4) Options Summary © 2001 E-Tech Security Products
PROGRAMMING OPTIONS SUMMARY
Przeglądanie stron 61
1 2 ... 57 58 59 60 61 62 63 64

Komentarze do niniejszej Instrukcji

Brak uwag