E-Tech ET8 Instrukcja Instalacji Strona 44

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 64
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 43
44
PROGRAMMING
E-TECH ET8 (V4) CONTROL PANEL INSTALLER MANUAL
CONTACT ID + AUDIBLE DTMF FORMAT
For simultaneous Central Station and Audible Monitoring.
The alarm message will be sent to the Central Station on the Primary telephone
number and then in audible DTMF format to the Follow Me telephone number.
PROGRAMMING SEQUENCE:
P86E 5E turns the option ON
P86E 5E ON: Contact ID + Audible DTMF format enabled
P86E 5E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF
NOTES:
Only one option in the range
P86E 1E6E is allowed to be ON
CONTACT ID + AUDIBLE PULSE FORMAT
For simultaneous Central Station and Audible Monitoring.
The alarm message will be sent to the Central Station on the Primary telephone
number and then in audible PULSE format to the Follow Me telephone number.
PROGRAMMING SEQUENCE:
P86E 6E turns the option ON
P86E 6E ON: Contact ID + Audible PULSE format enabled
P86E 6E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF
NOTES:
Only one option in the range
P86E 1E6E is allowed to be ON
ALARM EVENT
ACCOUNT
NUMBER Q XYZ GG CCC SUFFIX
Zones 1~8 Alarm AAAA Q 130 GG 001-008 k
Duress AAAA Q 121 01 030 k
Keyswitch Panic AAAA Q 120 01 031 k
Keypad Panic AAAA Q 120 01 032 k
Radio Key Panic AAAA Q 120 01 by User k
Medical Alarm AAAA Q 100 01 033 k
Fire AAAA Q 110 01 034 k
Exit Install mode AAAA Q 306 01 035 k
External Tamper AAAA Q 137 01 040 k
Internal Tamper AAAA Q 137 01 041 k
Keypad Tamper AAAA Q 137 01 042 k
Radio Sensor Tamper AAAA Q 383 01 by Device k
Test Report AAAA Q 602 01 063 k
Mains Fail AAAA Q 301 01 050 k
Panel Battery Fail AAAA Q 309 01 051 k
Open AAAA Q 402 GG by User k
Close AAAA Q 402 GG by User k
Cancel AAAA Q 406 GG by User k
Zones 1~8 Manual Exclude AAAA Q 573 GG 001-008 k
Zones Auto Exclude1~8 AAAA Q 380 GG 001-008 k
The ET8 reports alarms to the
Central Station using Contact ID
dialler format.
The message format is fixed as
shown in the Contact ID Codes
Table.
The message takes the form of:
AAAA Account Number (P72E)
Q Event qualifier
XYZ Alarm type
GG Group or Area designation
CCC Alarm number
Suffix Event checksum
CONTACT ID CODES TABLE
Przeglądanie stron 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 63 64

Komentarze do niniejszej Instrukcji

Brak uwag