52
PROGRAMMING
E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL
REQUIRED RINGS
Sets the number of double-rings before an incoming call is answered. This is
used for Remote Access.
Programmable from 1 to 16 rings. Enter a value between 1 and 16.
See below for a detailed description.
PROGRAMMING SEQUENCE:
P91E existing Required Rings value is displayed
[ENTER NEW VALUE] E new Required Rings value is displayed
EXAMPLE: To make Required Rings = 3:
P91E3E
P91E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
1
NOTES:
• RELATED OPTIONS:
P90E 1E to 8E (All Remote Access
options)
OPTION No DESCRIPTION DEFAULT NOTE
P91E Required Rings to answer 1
SEND DIALLER TEST REPORT
Send a Dialler Test Report in USER PROGRAM MODE. Obviously, at least one telephone
number must be programmed (P70E).
PROGRAMMING SEQUENCE:
P66666666E (eight 6’s) Triggers dialler and sends test report to Central Station
P66666666E
PROGRAM MODE LEVEL:
User Program Mode
FACTORY DEFAULT:
[not applicable]
SIREN TEST
Turn the Siren, Reset and Strobe Outputs On. Pressing P E will stop the Siren Test (and also
exits Program Mode).
PROGRAMMING SEQUENCE:
P77777777E (eight 7’s) Triggers Siren, Reset, Strobe
P77777777E
PROGRAM MODE LEVEL:
Installer, User Program Mode
FACTORY DEFAULT:
[not applicable]
PANEL RESET
This function resets the microprocessor. The effect is the same as powering down and
powering up again.
PROGRAMMING SEQUENCE:
P88888888E (eight 8’s) Panel Reset
P88888888E
PROGRAM MODE LEVEL:
Installer, User Program Mode
FACTORY DEFAULT:
[not applicable]
Komentarze do niniejszej Instrukcji