56
E-TECH RADIO
E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL
RADIO DEVICE PROGRAMMING
Each of the 8 zones of the ET8 can be a radio zone. Once programmed, zones
can accept both Radio Devices and normal zone inputs simultaneously.
The optional 100–200 E-Tech Radio Interface is required for Radio Devices to
operate.
A Radio Device is any type of E-Tech transmitter including Radio PIR, Radio
Reed Switches, Radio Smoke Detector.
PROGRAMMING RADIO DEVICES
Up to 8 Radio Devices can be assigned, (one per zone).
PROGRAMMING SEQUENCE – NO RESTORALS
Suitable for 100–663 Radio PIR, 100–665 Radio Pendant, 100–203 Radio
Smoke Detector.
Select a zone using
P01E – P08EP01E – P08E
P01E – P08EP01E – P08E
P01E – P08E
The ARMED light will be ON if a Radio Device is already programmed to the zone. Press 0E to delete.
Press
1E1E
1E1E
1E
The READY light will turn ON to indicate that the zone is ready to accept the Radio Device.
Trigger the Radio Device
A. If the Radio Device is accepted, the READY light will turn off, the ARMED light will turn on and 3 beeps
will sound.
B. If the READY light stays on and a warning beep sounds, the Radio Device is already assigned to
another zone and must be cleared from that zone first.
EXAMPLE: To program a Radio PIR on zone 1:
P01E 1E Trigger the Radio PIR (or simply connect the battery)
PROGRAMMING SEQUENCE – WITH RESTORALS
Suitable for 100–662 Radio Reed Switch.
Alarm the reed switch, ie., move the magnet away from the switch
Leave the reed switch in the alarm condition and wait until radio transmission has stopped.
Select a zone using
P01E – P08EP01E – P08E
P01E – P08EP01E – P08E
P01E – P08E
The ARMED light will be ON if a Radio Device is already programmed to the zone. Press 0E to delete.
Press
1E1E
1E1E
1E
The READY light will turn ON to indicate that the zone is ready to accept the Radio Device.
Restore the reed switch (place the magnet next to the switch)
A. If the Radio Device is accepted, the READY light will turn off, the ARMED light will turn on and 3 beeps
will sound.
B. The MEMORY light will turn on to indicate that this device sends Restorals.
C. If the READY light stays on and a warning beep sounds, the Radio Device is already assigned to
another zone and must be cleared from that zone first.
EXAMPLE: To program a Radio Reed Switch with Restorals on zone 2:
Alarm the reed switch P02E 1E Restore the reed switch
P01E ~ P08E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
No Radio Devices programmed
NOTES:
• Radio Device programming is done by
‘learning’ the code by radio.
• Radio Devices codes can only be deleted
by keypad.
• Some E-Tech Radio Devices send
separate Alarm and Restore signals.
• E-Tech Radio Keys (100–664), can also
be programmed to operate on radio
zones, but they are normally used to
operate Radio Codes as described on
page 57.
• Late model E-Tech Radio PIRs (100–663)
and Radio Reed Switches (100–662)
send Supervision signals.
SUPERVISION RELATED OPTIONS:
P65E Supervised Radio Zones
P66E 1E–8E Radio Supervision Alerts
P67E Radio Supervision Time
P75E 12E Radio Supervision Fail Report
• RELATED OPTIONS:
P09E–P10E Programming Radio Keys
RADIO DEVICES – OPTION TABLE
DELETING A RADIO DEVICE:
Use
P01E P01E
P01E P01E
P01E to
P08E P08E
P08E P08E
P08E to select the zone
Press
0E0E
0E0E
0E to clear the device (3 beeps will sound)
TIP: To prevent conflicting radio signals when programming Radio
Devices, disable each device once you have finished programming it.
(Remove the battery or open the RADIO link).
Remember to enable all the devices when programming is completed.